Reports

About Regulatory Reports

GE Digital APM provides following types of Regulatory reports, each of which reports a different set of data:

  • NERC Event Reports: Includes data about Events for which the Regulatory Organization is NERC. This report contains all NERC Events logged in a GAA Unit for a specified period. GE Digital APM provides the NERC GADS Event Report 07 in the baseline GAA NERC Report record that can be used to generate NERC Event report. The NERC GADS Event Report 07 returns event data in the 07 format required by NERC.
  • CEA Event Reports: Includes data about Events for which the Regulatory Organization is CEA. This report contains all CEA Events logged in a GAA Unit for a specified period. GE Digital APM provides the CEA Event Report in the baseline GAA NERC Report record that can be used to generate CEA Event report. The CEA Event Report returns event data in the Generation Equipment Status File format as specified by CEA.
  • NERC Performance Reports: Includes data about unit performance for the specified month.GE Digital APM provides the NERC GADS Performance Report 05 baseline GAA NERC Report record that can be used to generate NERC performance report. The NERC GADS Performance Report 05 returns performance data in the 05 format required by NERC. GE Digital APM also provides the CEA Performance Report which contains data based on NERC calculations.

All the Regulatory reports are downloaded as text files.

You can view a list of Regulatory reports configured for a GAA Unit only if the reports have been configured for a GAA Unit by the administrator.

About Management Reports

GE Digital APM provides three types of Management reports, each of which reports a different set of data:

Data Included in an Event Report

The Event Report contains the following sections:

  • A – Event Identification: Contains values from the following fields in Event records:
    • Record Code: For a NERC GADS Event Report 07, the value in this field is 07.
    • Primary Utility Code
    • GADS Unit Code
    • Reporting Year
    • Event Number
    • Revision
    • Event Type
  • B – Event Magnitude: Contains values from the following fields in Event records:
    • Event Start
    • Event End
    • Gross Available Capacity
    • Net Available Capacity
    • Dominant Derate
    • Dominant Derate
    • Record Number
  • C – Primary Cause of Event: Contains values from the following fields in Event records:
    • Cause Code System
    • Amplification Code
    • Work Started
    • Work Ended
    • Event Contribution Code
    • Problem Alert
    • Man-hours Worked
    • Verbal Description
  • D – Additional Work During Event: Contains values from the following fields in Event records:
    • Cause Code System
    • Amplification Code
    • Work Started
    • Work Ended
    • Event Contribution Code
    • Problem Alert
    • Man-hours Worked
    • Verbal Description
    Note:

    In NERC Event reports, the following values are gathered only from Primary Event records:

    • Event End
    • Event Start
    • Work Ended
    • Work Started

    The values in the above fields from the Contributing Event records are not used.

Data Included in a Performance Report

The Performance Report contains the following sections:

  • A – Unit Identification: Contains values from the following fields in Performance records:
    • Record Code: For a NERC GADS Performance Report 05, the value in this field is 05.
    • Utility Code
    • Unit Code
    • Reporting Year
    • Reporting Month
    • Revision
  • B – Unit Generation Performance: Contains values from the following fields in Performance records:
    • Gross Maximum Capacity
    • Gross Dependable Capacity
    • Gross Actual Generation
    • Net Maximum Capacity
    • Net Dependable Capacity
    • Net Actual Generation
  • C – Unit Starting Characteristics: Contains values from the following fields in Performance records:
    • Typical Unit Loading Characteristics
    • Attempted Unit Starts
    • Actual Unit Starts
    • Verbal Description
    • Record Number
  • D – Unit Time Information: Contains values from the following fields in Performance records:
    • Service Hours
    • Reserve Shutdown Hours
    • Pumping Hours
    • Synchronous Condensing Hours
    • Available Hours
    • Planned Outage Hours
    • Forced Outage Hours
    • Maintenance Outage hours
    • Extensions of Scheduled Outages Hours
    • Unavailable Hours
    • Period Hours
    • Inactive Hours
    • Record Number
  • E – Primary Fuel: Contains values from the following fields in Performance records:
    • Fuel Code
    • Quantity Burned
    • Average Heat Content
    • Percent Ash
    • Percent Moisture
    • Percent Sulfur
    • Percent Alkalines
    • Grindability Index
    • Ash Softening Temp
  • F – Secondary Fuel: Contains values from the following fields in Performance records:
    • Fuel Code
    • Quantity Burned
    • Average Heat Content
    • Percent Ash
    • Percent Moisture
    • Percent Sulfur
    • Percent Alkalines
    • Grindability Index
    • Ash Softening Temp
    • Record Number

Data Included in an Events Based on Cause Code and Date Report

The Events Based on Cause Code and Date Report contains the following fields, which contain values from the Event record.

  • Unit ID
  • Unit Name
  • Plant Name
  • Event Number
  • Event ID
  • Capacity Event Type
  • Event Start Date
  • Event End Date
  • Cause Code System
  • Cause code Component
  • Cause Code
  • Amplification Code
  • Verbal Description

Access a Regulatory Report

Before you begin

  • Configure and associate a Report

Procedure

  1. Access the GAA Overview page.
  2. Select the Generation Reports tab.

    A list of GAA reports appears, displaying the following columns of information:

    • Report ID
    • Unit ID
    • Modified By
    • Last Modified

  3. In the Report ID column, select the link to the Regulatory report that you want to access.
    Tip: All the Regulatory reports are text files.

    The Save As window appears.

    Note: These steps may change depending on the browser and browser settings that you use.
  4. Navigate to the location to which you want to save the report.
  5. In the File name box, enter the name of the file, and then select Save.

    The report is saved to the selected location. The Regulatory report is saved as a text file as per NERC requirement. You can send this report directly to NERC.

Generate a Regulatory Report

Before you begin

  • Configure and associate a Report

Procedure

  1. Access the GAA Overview page.
  2. Select the Generation Reports tab.

    A list of GAA reports appears.

  3. In the upper-right corner of the Generation Reports section, select Manage Reports.

    The Units window appears.

    Note: The Units window will appear if there is more than one GAA Unit. If there is only one GAA Unit, the Performance & Reports workspace appears, displaying the Regulatory Reports section. If this occurs, proceed to step 6.

  4. Select the GAA Unit for which you want to generate a Regulatory report.
    Note: You can generate only the reports that you have configured and associated with the selected GAA Unit.
  5. Select Open Reports.

    The Performance & Reports workspace appears, displaying the Regulatory Reports section.

  6. For the month for which you want to generate a Regulatory report, in the Created On column, select Generate Report.

    The report is generated and saved to the Reference Document family.

    The following columns of information are updated in the Regulatory Reports section:

    • Report Name: Contains the name of the report. The name of the report appears in the following format:

      <Regulatory Organization> <Report Name> <Reporting Month> <Reporting Year>.txt

      • If the report is generated, the name appears as a hyperlink and the date when the report was generated appears in the Created On column.
      • If the report is not generated, the name appears as plain text and the Generate Report button appears in the Created On column.
    • Report Type: Indicates whether the report is an Event report or a Performance report.
    • Created By: Indicates the user who generated the report.
    • Created On: Contains the date when the report was generated.

    By default, the reports appear for the current year. If you want to view reports for a previous year, you can select to specify a different year.

    Note: For a GAA Unit that reports to CEA, in the regulatory report, the Common Mode Outage, Auxiliary Number, and Selected Component Outage fields will be blank. Also, in a GAA Unit, if the Primary Regulatory Body and Secondary Regulatory Body are configured, then the report will be generated for both.

Generate a Management Report

Before you begin

  • Configure and associate a Report

Procedure

  1. Access the GAA Overview page.
  2. Select the Generation Reports tab.

    A list of GAA reports appears.

    Note:

    You can also generate a Management report via the Management Reports section. To do so:

    1. In the upper-right corner of the Generation Reports section, select Manage Reports.

      The Units window appears. The Units window will appear if there are more than one GAA Units. If there is only one GAA Unit, the Performance & Reports workspace appears, displaying the Regulatory Reports section.

    2. Select the GAA Unit for which you want to generate a Management report.

    3. Select Open Reports.

      The Performance & Reports workspace appears, displaying the Regulatory Reports section.

    4. Select the Management Reports tab.

      A list of Management Reports appears, displaying links for the various Management reports.

  3. In the Report ID column, as needed, select a link for an Event report, Performance report, or Events Based on Cause Code and Date report.
    Note: You can generate only the reports that you have configured and associated for the selected GAA Unit.

    The Enter Parameter Values window appears. The following image shows the Enter Parameter Values window when you select the link for an Event report.

  4. If you selected Event or Performance report in the previous step, enter the values in the following fields:
    • In the Unit ID cell, enter the ID of the Unit for which you want to generate a report.
    • In the Reporting Month cell, enter the month for which you want to generate a report.
    • In the Reporting Year cell, enter the year for which you want to generate a report.

    If you selected Events Based on Cause Code and Date report in the previous step, enter the values in the following fields:

    • In the Unit ID cell, enter the ID of the Unit for which you want to generate a report.
    • In the Start Date cell, enter the date when the Event started.
    • In the End Date cell, enter the date when the Event ended.
    • In the Cause Code System cell, select the value for which you want to generate a report.
  5. Select Done.

    The Management report is generated and appears in a new tab. The following image shows the Performance report.

Regenerate a Regulatory Report

Before you begin

Procedure

  1. Access the GAA Overview page.
  2. Select the Generation Reports tab.

    A list of GAA reports appears.

  3. In the upper-right corner of the Generation Reports section, select Manage Reports.

    The Units window appears.

    Note: The Units window will appear if there are more than one GAA Units. If there is only one GAA Unit, the Performance & Reports workspace appears, displaying the Regulatory Reports section.
  4. Select the GAA Unit for which you want to regenerate a Regulatory report.
  5. Select Open Reports.

    The Performance & Reports workspace appears, displaying the Regulatory Reports section.

  6. For the month for which you want to regenerate a Regulatory report, locate the row containing the report that you want to regenerate.
    Note: Regardless of which Event report you select to regenerate, both the Event Reports are regenerated. For example, if you select Event report for NERC to regenerate, the Event report for CEA is also regenerated, and vice versa.
  7. In the upper-right corner of the section, select .

    The Regenerate Report dialog box appears, asking you to confirm that you want to regenerate the selected report.

  8. Select Yes.

    The selected report is regenerated.

Delete a Regulatory Report

Procedure

  1. Access the GAA Overview page.
  2. Select the Generation Reports tab.

    A list of GAA reports appears.

  3. In the upper-right corner of the Generation Reports section, select Manage Reports.

    The Units window appears.

    Note: The Units window will appear only if there is more than one GAA Unit. If there is only one GAA Unit, then the Performance & Reports workspace appears, displaying the Regulatory Reports section.
  4. Select the GAA Unit for which you want to regenerate a Regulatory report.
  5. Select Open Reports.

    The Performance & Reports workspace appears, displaying the Regulatory Reports section.

    <Image>

  6. For the month for which you want to delete a Regulatory report, locate the row containing the report that you want to delete.
  7. In the upper-right corner of the section, select .

    The Delete Report dialog box appears, asking you to confirm that you want to delete the selected report.

  8. Select Yes.

    The selected report is deleted.