2.5.1. Enter PRT Graphic Display General Specifications

About this task

Select the General tab in the PRT Graphic Display Configuration dialog box.

Important:  
  • The Display Point must be created/selected first in order have access to the appropriate values in the other fields.
  • The fields on the PRT Graphic Display Configuration dialog box>General tab above the Display Point field must be configured in order to access the Global tab.
A Display Point
B Display Point Enabled Top Fields
  1. Display Point

Procedure

  1. Click the Popup Menu button to the right of the Display Point field.
  2. Select New on the Popup menu.

    A New Point dialog box opens.

  3. Enter and select the following.
    A Point ID RED_COUNT
    B Type Virtual
    C Class Analog
  4. Click OK.

    The RED_COUNT Point Properties dialog box opens.

  5. Leave the defaults on the General tab, including:
    Data Type Int
    Elements 1
  6. Select the Virtual tab.
  7. Enter and select the following.
    A Initialization Initialized
    B Initial value 0
    C Calculation None
  8. Click OK.

Results

Result: RED_COUNT is entered in the Display Point field.

  1. Display Point Enabled Top Fields

Select the following options.

A Region SCHEDULE
B Attribute PRT_ITEM_STATUS
C Operator Equals (=)
D Value 1