8.3.4. Create a New Output Logic Module (OLM)
About this task
The Output Logic Module will set the attributes of your product with the point values that you set using the CIMPLICITY screen.
A |
Create an AddParts Output Logic Module
|
B | Select the Set Attribute with Point Function Block |
C | Configure the Set Attribute with Point Block |
- Create an AddParts Output Logic Module
Procedure
- Click the Popup Menu button to the right of the Output Logic Module field.
-
Select New on the Popup menu.
An Output Logic Wizard opens.
-
Enter the following.
1 Name AddParts 2 Description Add Parts RCO Output Logic 3 Click the New button on the Output Logic Wizard toolbar. A Select a Function Block browser opens.
- Select the Set Attribute with Point Function Block
- Expand the Core folder in the Select a Function Block browser.
-
Double-click
Set Attribute with Point
.
Results
A Set Attribute with Point dialog box opens.
- Configure the Set Attribute with Point Block
Do the following.
1 | Description |
2 | Region Id |
3 | Region Location |
4 | Item Class |
5 | Attribute ID |
6 | Point Name |
7 | OK Button |
1 | Description |
Enter Set CPU Ser #.
2 | Region Id |
- Double-click Region Id.
A P1 dialog box opens.
- Select the LOAD region in the Region Id dropdown menu.
- Click OK.
3 | Region Location |
Leave the default First Region Location value in the Region Location field.
4 | Item Class |
- Double-click Item Class.
A P3 dialog box opens.
- Select the BLOCK class in the Item Class dropdown menu.
- Click OK.
5 | Attribute ID |
- Double-click Attribute Id.
A P4 dialog box opens.
- Select the CPU Serial # class in the Attribute Id dropdown menu.
- Click OK.
6 | Point Name |
- Double-click Point Name.
A P5 dialog box opens.
- Click the Popup Menu button to the right of the Point Name field; select Browse on the Popup menu.
A Select a Point browser opens.
- Select CPUSERIAL.
Note: CPUSERIAL is the point that you created for the attrentry.cim screen
- Click OK.
7 | OK Button |
Click OK on the Set Attribute with Point dialog box.
The Output Logic Wizard now has Set CPU Ser # in the Function Blocks list box.