Error Messages from Point Translation Process
Error codes that can be sent from the Point Translation Process are:
Number | Defined Constant | Description |
---|---|---|
26000 | PTX_NORMAL | Normal successful completion |
26001 | PTX_UNKNOWN_SEGMENT | Unknown Segment Sent - See err_ref for Segment Number |
26002 | PTX_MISSING_DEVCOM_PROC | Devcom process ID not found in SC files |
26003 | PTX_FR_NOT_FOUND | Factory resource ID not found in data base |
26004 | PTX_POINT_NOT_FOUND | Point ID not found in data base |
26005 | PTX_PTMGMT_OWNER_NOT_FOUND | Point Manager owner not found in data base |
26006 | PTX_HAS_NOT_EU_CONV | Specified Point has no Eu Conversion |
26007 | PTX_PT_TYPE_OWNER_NOT_FOUND | Point Type owner not found in data base |
26009 | PTX_DEVICE_NOT_IN_SC | No Device in SC device file for devcom proc = |
26010 | PTX_PTMGMT_DEVCOM_DB | No Point Manager in DB for devcom proc = |
26011 | PTX_DERIVE_PT_NOT_IN_SC | Point not found in SC derive file = |
26012 | PTX_PTMGMT_DERIVE_PT_DB | No point manager in DB for derive point = |
26013 | PTX_PTMGMT_OWN_DEVICE_DB | No point manager in DB for device point = |
26014 | PTX_DEVICE_NOT_IN_DB | No device in DB for device id = |
26015 | PTX_DEVICE_PT_NOT_IN_SC | Point not found in SC device file = |
26016 | PTX_PT_TYPE_NOT_IN_DB | No point type in DB for point = |
26017 | DYN_CFG_SEG_ERR | Unrecognized segment in dyn cfg msg |
26018 | DYN_CFG_BAD_KEY_ERR | Key not valid for %s file |
26019 | DYN_CFG_NO_FILE_ERR | Could not write sc_path:dyn_cfg.cfg |
26020 | DYN_CFG_BAD_SEQ_ERR | Unexpected sequence number |
26021 | DYN_CFG_BAD_SENDER_ERR | Unexpected sender: |
26022 | PTX_PT_STRUCT_NOT_VALID | Structure point is not properly defined for type = |
26030 | PTX_ADHOC_NO_ADDRESS | Point By Address requires a Device Address |
26030 | PTX_ADHOC_NO_DEVICE | Point By Address requires a Device Specification |
26030 | PTX_ADHOC_DEV_NOTFOUND | Point By Address Device (%.32s) not found. |
26030 | PTX_ADHOC_PTM_NOTFOUND | Point By Address Device (%.32s) has not Point Manager. |
26030 | PTX_ADHOC_TYPE_NOTFOUND | Point By Address Type (%.32s) not found. |
26030 | PTX_ADHOC_BAD_SCAN | Invalid Point By Address Scan Rate (%.20s). |
26030 | PTX_ADHOC_BAD_OFFSET | Invalid Point By Address Bit Offset (%.20s). |
26030 | PTX_ADHOC_BAD_ELEM | Invalid Point By Address Array Elements (%.20s). |
26030 | PTX_ADHOC_BAD_ACCESS | Invalid Point By Address Access Mode (%.20s). |
26030 | PTX_ADHOC_BAD_ADDR_TYPE | Invalid Point By Address Address Type (%.32s). |
26040 | PTX_ADHOC_BAD_TYPE | Invalid Point By Address Data Type (%.32s). |
26041 | PTX_ERR_EXTREF_INV_REF | Invalid concentrated point reference (%s) |