10.3. Use the Global Parameter Synchronization Capability
About this task
The auto_move_point field in the PRT_REGION file supplies the ID of a text point to be set when an item moves into a tracking region due to a "point-based" automatic move.
This point is set according to the value of the NUM_SETPT_PARAM parameter in the global parameters file.
Procedure
Expand the Project>Advanced folder in the Workbench left-pane.
Double-click the Project Parameters icon .
A New Global parameter dialog box displays.
Enter NUM_SETPT_PARAM in the New Global Parameter dialog box.
Click OK.
Global Parameter - NUM_SETPT_PARAM dialog box opens.
Enter one of the following values.
Value
Sets the point with the:
1
Item ID (Also if the parameter is not present.)
2
Item ID and Type
3
Item ID, Type and Reference ID
4
Item ID, Type Reference ID and Source Region
Note: You view the points values in the Point Control Panel when you move items through the system.