PMC Data Window Error Handling

Return Meaning Explanation  Error Handling
EW_PROTOCOL (-17)
Protocol error Ethernet version only Data from Ethernet Board is incorrect. Contact with the service section or the section in charge.
EW_SOCKET (-16)
Socket error Ethernet version only Investigate CNC power supply, Ethernet cable and I/F board.
EW_NODLL (-15)
DLL file error There is no DLL file for each CNC series corresponding to specified node.
EW_BUS (-11)
Bus error HSSB version only A bus error of CNC system occurred. Contact with the service section or the section in charge.
EW_SYSTEM2 (-10)
System error (2 HSSB version only A system error of CNC system occurred. Contact with the service section or the section in charge.
EW_HSSB (-9)
Communication error of HSSB HSSB version only Investigate the serial line or I/F board of HSSB.
EW_HANDLE (-8)
Handle number error Get the library handle number.
EW_VERSION (-7)
Version mismatch between the CNC/PMC and library The CNC/PMC version does not match that of the library. Replace the library or the CNC/PMC control software.
EW_UNEXP (-6)
Abnormal library state An unanticipated error occurred. Contact with the section in charge.
EW_SYSTEM (-5)
System error HSSB version only A system error of CNC occurred. Contact with the service section or the section in charge.
EW_PARITY (-4)
Shared RAM parity error HSSB version only A hardware error occurred. Contact with the service section.
EW_MMCSYS (-3)
FANUC drivers installation error HSSB version only The drivers required for execution are not installed.
EW_OK (0)
Normal termination
EW_NOPMC (1)
Error (No PMC) The PMC does not exist.
EW_LENGTH (2)
Error (data block length error) Check and correct the data block length.
EW_RANGE (3)
Error (address range error) Check and correct the address range.
EW_TYPE (4)
Error (address type/data type error) Check and correct the address type/data type.
EW_DATA (5)
Error (data error) Check and correct the data.
EW_NOOPT (6)
Error (no option) There is no corresponding CNC option.
EW_BUFFER (10)
Error (buffer empty/full) The buffer is empty or full. Wait until completion of PMC processing, or retry. Alternatively, add the required processing for the PMC.
EW_PASSWD (17)
Error (State of data protection) Data is protected by the CNC data protection function.