Predix Edge Applications and Services Release Notes 2.3.2

Bug Fixes

This release contains the following bug fixes:
OPC-UA Adapter Polling
1. Resolved an issue where OPC-UA adapter polling would stop processing data in a block once a tag with bad data quality was encountered. This issue exists in Predix Edge releases 2.3 and 2.3.1.
Cloud Gateway
Resolved several resource leaks and stability issues within the Cloud Gateway.

Known Issues

This release has the following known issues:
Raspberry Pi
Cloud Gateway on Raspberry Pi is known to fail after running for an extended period of time, due to insufficient memory on the Raspberry Pi device.
Note: The Raspberry Pi image remains unchanged from the 2.1.0 release.
Cloud Gateway Performance
When the cloud connection is re-established and there is a large store buffer, cloud gateway performance will be slow for a couple of minutes.
Raw Modbus Data
Raw modbus data passed from an adapter into a raw modbus sink will fail with an error similar to:
  • Couldn't parse {"data":{"tagName":{"val":19}},"timestamp":1562096019014}: std::exception