Third Quarter of 2019

Analysis

This topic provides a list of product changes released for this module on the dates listed below.

Release Date: September 27, 2019

Table 1. Enhancements and New Features

The following enhancements and new features have been added.

DescriptionTracking ID
You can now set the permissions on Analysis templates to share the template across all the enterprises.
Note: To enable this functionality, you must have the Create Tenant Level Template permission. This permission, when enabled, allows the user to set the visibility of any analysis class template to be accessible for any newly added enterprises after the template creation.
US360472
You can now create public analysis templates that are available to all the users in a tenant. To enable this functionality, you must have the required permissions. F46552
You can now configure all the parameters in an Analysis template before you load a saved template. This allows you to load the data in the format that you want. F46551
You can now configure the SmartSignal chart series settings and other settings at a card level. This allows you to configure the series that you want to enable for the tags in each of the charts in the card. You can also set other settings for the cards such as enabling automatic thresholds on the charts and filtering the data on the charts by using mode thresholds. F46364
  • You can now view the asset name along with the tag name in the tag register for normal charts.
  • You can now add a loading indicator to all the charts when the charts are waiting for data.
  • You can now scale the actual or estimate charts based on the data instead of the thresholds on the charts.
F44252
You can now add a SmartSignal tag or a group of tags anywhere in the SmartSignal Card. F43749
You can now view an evidence that is attached to a case up to the current time. This allows you to see the change that has occurred since the time the evidence was saved to the case. F41107
Table 2. Known Issues

The following issues are unresolved in this release.

DescriptionTracking ID
When you have multiple y-axes enabled on a Time-Series chart, Y zoom and XY zoom provide an inconsistent user experience because all the axes do not scale correctly to reflect the zoomed-in state.DE104375
If you point to a diagnostic marker on a SmartSignal chart, no information appears. To exit the mode and view the information about the marker, refresh the charts.DE101633
If you enable the cross-hair mode in an analysis and then add new charts to the template, the cross-hair information is not reflected on the new charts, and the cross-hair markers are no longer visible on the existing charts. To prevent this, disable cross-hair mode, add the charts, and then enable the cross-hair mode again.DE99126
When you delete tags on a Time-Series chart after you have plotted pin markers, the deleted tags appear in the marker data table. To prevent this issue, delete the tags, and then set the pins on the charts.DE95436
While modifying the Time-Series chart in multiple y-axes mode, if you select Apply, your changes are neither applied nor visible in the chart settings. To prevent this issue, select Cancel, and then create the template for an ad hoc view. Alternatively, you can save the template, and then modify the existing template as needed.DE93811
You must use Google Chrome to add multiple charts to a SmartSignal card.
Note: Other browsers, including Internet Explorer, are not supported when adding multiple charts to a single SmartSignal card.
None