9F.03/9F.04 Gas Turbine (50 Hz)
With more than 200 installed units worldwide, and an excess of 12 million operating hours, the 9F.03 and 9F.04 heavy-duty gas turbines are excellent for a wide range of applications.
- Improved survivability from grid disruptions and load transients
- OpFlex AutoTune, which improves Dry Low NOx (DLN) operability and eliminates firing-temperature suppression
- 18-stage compressor with variable inlet guide vanes to reduce degradation and stress on wear-related components
- DLN 2.6+ combustor provides dual-fuel capability and enables turndown to 35 percent of baseload in simple cycle
- Three-stage hot gas path (HGP) turbine has advanced cooling and sealing improves efficiency and provides lowest lifecycle cost in its class
- More than 97 percent average start-up reliability
- Improved compressor that increases reliability and availability, while reducing periodic inspections and maintenance costs
FORMER NAMES:
Frame 9F, 9F 3-Series, 9F-3, 9FA+e, 9FA.03, 9351(FA), PG9351FA, 9FA+, 9FA.02, 9331(FA), PG9331FA, 9FA, 9FA.01, 9311(FA), PG9311FA, MS9001(FA)
Featured Services
GE empowers you with total lifecycle solutions tailored to your desired outcomes. Our advanced technology and service solutions deliver industry-leading value to your products.
Product Specifications
9F |
9F.03 | 9F.04 |
---|---|---|
50/60 | 50 HZ | 50 HZ |
SC Output (MW) |
265 | 288 |
SC Net Heat Rate (Btu/kWh, LHV) |
9020 | 8810 |
SC Net Heat Rate (kJ/kWh, LHV) |
9517 | 9295 |
SC Efficiency (%, LHV) |
37.80% | 38.7% |
9F |
9F.03 | 9F.04 |
---|---|---|
Block Configuration (GTs x STs) |
1x1 | 1x1 |
CC Net Output | 412 | 443 |
CC Net Heat Rate (Btu/kWh, LHV) |
5778 | 5666 |
CC Net Heat Rate (kJ/kWh, LHV) |
6096 | 5978 |
CC Net Efficiency (%, LHV) |
59.1% | 60.2% |
Plant Turndown - Minimum load (%) |
46% | 48% |
Ramp Rate (MW/minute) |
22 | 22 |
Startup Time (Hot, minutes) |
30 | 30 |
9F |
9F.03 | 9F.04 |
---|---|---|
Block Configuration (GTs x STs) |
2x1 | 2x1 |
CC Net Output (MW) |
825 | 889 |
CC Net Heat Rate (Btu/kWh, LHV) |
5764 | 5649 |
CC Net Heat Rate (kJ/kWh, LHV) |
6081 | 5960 |
CC Net Efficiency (%, LHV) |
59.2% | 60.4% |
Plant Turndown - Minimum load (%) |
21% | 22% |
Ramp Rate (MW/minute) |
44 | 44 |
Startup Time (Hot, minutes) |
39 | 39 |