Benefits

How 7F AGP responds to your needs

Many power producers have specific goals—widening operational range and improving heat rate for efficient power generation can have a measurable impact. The 7F AGP is a set of solutions that can be configured to achieve the level of output you need given your operating profile.

7F AGP can answer your concerns, in an industry where incremental changes to boost performance and production can expand capacity in a meaningful way.

Solutions

7F AGP options, find your path

Choose the solution that aligns with your plant and specific goals.

  • 7F.03 Simple Cycle
  • 7F.03 Combined Cycle
  • 7F.04 SC
  • 7F.04 CC
  • 7F.05 SC
  • 7F.05 CC

AGP upgrades options can improve output, efficiency, and reliability of your 7F.03 unit. The right package depends on existing equipment and operating budget.

 

  AGP Peaker AGP Flex AGP Standard AGP Tech
Best for: Customers looking for a budget option to increase output on a simple cycle unit.

Customers looking for flexible, partial AGP applications.

Customers looking to achieve moderate output gains without the large investment of AGP Tech.

Customers looking to reduce CAPEX and add value to enhance the performance of their existing infrastructure.

Output: up to 4%

up to 5%

up to 5.3%

up to 12%

Megawatts gained:        
Heat rate: up to -1%     up to -1.3% up to -1.9%
up to -2.5%
Hot gas path intervals: 10-16k
24-32k
32k
32k
Cost: $$$$ $$$$ $$$$ $$$$
Additional requirements:

Controls adjustments

Controls adjustments

Controls adjustments

Controls adjustments and DLN2.6+

 

Results for a given project will be a function of gas turbine model, ambient conditions, emission requirements, and other site-specific requirements.

AGP upgrades options can improve output, efficiency, and reliability of your 7F.03 unit. The right package depends on existing equipment and operating budget.

 

  AGP Flex AGP Standard AGP Tech
Best for:

Customers looking for flexible, partial AGP applications.

Customers looking to achieve moderate output gains without the large investment of AGP Tech.

Customers looking to reduce CAPEX and add value to enhance the performance of their existing infrastructure.

Output:

up to 4.5%

up to 4.5%

up to 11.7%

Megawatts gained:      
Heat rate: up to -1% up to -1.3%
up to -2%
Hot gas path intervals:
24-32k
32k
32k
Cost: $$$$ $$$$ $$$$
Additional requirements:

Controls adjustments

Controls adjustments

Controls adjustments and DLN2.6+

 
Results for a given project will be a function of gas turbine model, ambient conditions, emission requirements, and other site-specific requirements.

Your 7F.04 unit can improve output and reliability with an AGP Tech conversion upgrade.

 

  AGP Tech Conversion
Best for:

Customers looking to reduce CAPEX and add value to enhance the performance of their existing infrastructure.

Output:

up to 5.4%

Megawatts gained:  
Heat rate:
up to -0.4%
Hot gas path intervals:
32k
Cost: $$$$
Additional requirements:

Controls adjustments and DLN2.6+

 
Results for a given project will be a function of gas turbine model, ambient conditions, emission requirements, and other site-specific requirements.

Your 7F.04 unit can improve output and reliability with an AGP Tech conversion upgrade.

 

  AGP Tech Conversion
Best for:

Customers looking to reduce CAPEX and add value to enhance the performance of their existing infrastructure.

Output:

up to 6%

Megawatts gained:  
Heat rate:
up to -0.6%
Hot gas path intervals:
32k
Cost: $$$$
Additional requirements:

Controls adjustments and DLN2.6+

 
Results for a given project will be a function of gas turbine model, ambient conditions, emission requirements, and other site-specific requirements.

Your 7F.05 unit can deliver its high level performance with an AGP Tech conversion.

 

  AGP Tech Conversion
Best for:

Customers looking to reduce CAPEX and add value to enhance the performance of their existing infrastructure.

Output:

up to 5.5%

Megawatts gained:  
Heat rate:
up to -0.7%
Hot gas path intervals:
32k
Cost: $$$$
Additional requirements:

Controls adjustments and DLN2.6+

 
Results for a given project will be a function of gas turbine model, ambient conditions, emission requirements, and other site-specific requirements.

Your 7F.05 unit can deliver its high level performance with an AGP Tech conversion.

 

  AGP Tech Conversion
Best for:

Customers looking to reduce CAPEX and add value to enhance the performance of their existing infrastructure.

Output:

up to 6.5%

Megawatts gained:  
Heat rate:
up to -1%
Hot gas path intervals:
32k
Cost: $$$$
Additional requirements:

Controls adjustments and DLN2.6+

 
Results for a given project will be a function of gas turbine model, ambient conditions, emission requirements, and other site-specific requirements.

Enhanced technology

What you get with an AGP upgrade

We have re-worked all three stages of buckets, nozzles, and shrouds as part of a systemic approach in which each component complements its counterparts for enhanced overall performance.

  • Refined aerodynamics and better sealing for higher efficiency performance
  • Advanced materials for more durability and reduced component stress
  • Improved cooling technology for higher operating temperatures and greater output
Contact us

Learn how 7F AGP can improve output and performance